Electric Fencing
All services in Kumasi
CAM 02 // PERIMETER FENCE LINE

Perimeter Electric Fencing with Proper Earthing & Alarm Siren

Perimeter fencing for boundary walls, installed with certified high-voltage energizers, deep earthing, and alarm sirens.

ENGINEER-LED INSTALLATION

Planned conduit routing, mathematically calculated electrical loads, certified earthing, and full post-commissioning handover in Kumasi.

On-Site Survey
Sunday to Friday in Kumasi
System Overview

About This Installation

An electric fence acts as both a formidable physical deterrent and an active detection boundary on top of perimeter walls. It delivers a high-voltage, non-lethal regulated shock pulse that prevents intrusion and triggers an immediate alarm siren if wires are cut, touched, or tampered with.

Because our team is engineer-led, we pay special attention to tensioning, post anchoring, insulation quality, and earthing depth. Proper earthing is the single most critical factor that determines shock effectiveness in Ghanaian soil. We install dedicated copper earth pits to ensure optimal stopping power.

Engineering Benchmarks & Quality Standards

8,000V to 10,000V regulated non-lethal deterrent shock pulse
Immediate 120dB alarm siren & strobe flash on wire cut or tamper
Triple copper earth rod pit tested to low resistance (< 5Ω)
Internal backup battery maintaining active security during blackouts

What you need to decide before installation

  • Line Count: Standard wall-top fences usually run 6, 8, or 10 lines depending on wall height and required deterrence.
  • Wall Condition: Existing perimeter wall masonry must be inspected for stability and level coping before post anchoring.
  • Siren & Strobe Placement: Positioning the alert siren and strobe light where neighbors or security guards can readily hear and see them.
  • Gate Integration: Bridging the fence across sliding gates or pedestrian entrances with insulated under-gate cables.
  • Backup Battery Capacity: Keeping the energizer active during local power outages.

What our installation involves

  1. 01Boundary inspection, measuring perimeters and verifying wall structural integrity.
  2. 02Anchoring heavy-duty galvanized or powder-coated posts with heavy fasteners at regular intervals.
  3. 03Threading high-tensile wire through UV-stabilized insulators with line tensioners and compression springs.
  4. 04Driving dedicated copper earth rods deep into the soil and testing resistance values.
  5. 05Connecting the certified energizer, backup battery, siren, and key switch, followed by high-voltage pulse testing.
Proof of Work

Recent Electric Fencing Jobs in Kumasi

All Projects Gallery
Wide view of luxury residential compound in Kumasi with complete Lite-Tek electric perimeter fence
CAM 01 // TAFO PERIMETER
Tafo

Full Compound High-Voltage Perimeter Electric Fence

Complete perimeter wall-top security envelope featuring multi-strand high-tensile wire, certified Nemtek energizer, 120dB alert siren, and deep low-resistance copper earthing.

Completed wall-top electric security fence installed on concrete boundary in Danyame, Kumasi
CAM 04 // DANYAME BOUNDARY
Danyame

Multi-Pillar Wall-Top Security Fence & Perimeter Hardening

Precision-drilled wall-top electric fencing mounted across masonry pillars with UV-stabilized bobbins, heavy-duty anchor brackets, and zoned warning signage.

Close-up of high-voltage electric fence corner posts with official Nemtek warning signs
CAM 08 // NHYIAESO CORNER
Nhyiaeso

Nemtek Certified High-Tension Corner Post Assembly

Heavy-duty galvanized corner strainers with compression springs, high-grade ceramic bobbins, and statutory high-visibility electric fence warning plates.